MP Battery Disconnect Isolator / Circuit Breaker 15 – 70amps
Min / Max Ultimate Trip: Must Hold 100% of rated current at 25°C/77°F. Must Trip at 135% of rated current within 1 hour. Unique / specific higher ambient calibrations are available
Interrupt Capacity: Per SAE J553 & UL1077* (U3) at 14 & 28VDC, 1.5kA @ 14VDC per ABYC (SAE J553 & UL1077* U3), 3kA @ 14VDC
Mounting eyelet hole size #10 with #8-32 nuts pre-installed
Ignition Protection: ISO 8846*, USCG, ABYC, UL1500* and SAE J1171
Dielectric Strength: 2000VAC minimum UL1107. Housing: Thermoplastic
Shock, Vibration, Corrosion: MIL-STD-202, UL1077*, UL1107*
Endurance: Per SAE J553 (100 overload trip cycles at 400% of rated current at 28VDC)
Operating Temperature: -40°C to 85°C
Inrush Capacity: The Series 53 will not trip at 35X rated capacity for ½ cycle (0.008 sec.)
Note: This product is not rated for an engine starter circuit. *Tested per methods of standard.
Approvals: UL 1077, SAE J553, ABYC, CE